INTRODUCTION
PRINCIPLE
INDICATIONS FOR USE
INTRODUCTION
We would like to thank you for making a smart decision! The
Blood Glucose Monitoring System is designed for Canadian.
The compact and portable Blood Glucose Meter is easy to use,
and displays test results in only 6 seconds.
In addition, the meter automatically stores up to 960 test records with
respective dates and times, which allows you to monitor your diabetic
program efficiently.
Thanks again for your support. Before testing, please read this User's
Guide thoroughly. It contains all the information you need regarding
the Blood Glucose Monitoring System. If you have questions
or need assistance, please call our Customer
A
ssistance line at
1-855-634-7873. For customer assistance outside the operational days
and times, please contact your health care provider with questions.
PRINCIPLE
The Blood Glucose Monitoring System is designed to provide
an easy, accurate method for determining capillary blood glucose values.
This analysis is based on amperometric technology using glucose oxidase
that is specific for the blood glucose measurement. When the blood
sample is applied to the test strip, electrons are formed by the reaction
between glucose oxidase and blood glucose. The electrical current is
measured by the meter and correlates with the concentration of glucose
in the blood sample.
INDICATIONS FOR USE
The Blood Glucose Monitoring Systems is intended for
use in the quantitative measurement of glucose in fresh capillary whole
blood from the finger. It is intended for use by lay users and should be
used by a single patient as an aid in monitoring the effectiveness of
diabetes control program. It is not intended for the diagnosis of or
screening for diabetes mellitus, and is not intended for use on neonates.
Medi+Sure
TM
Medi+Sure
TM
Medi+Sure
TM
Medi+Sure
TM
Medi+Sure
TM
Vista de pagina 0
1 2 3 4 5 6 ... 32 33

Indice de contenidos

Pagina 1 - Medi+Sure

INTRODUCTIONPRINCIPLEINDICATIONS FOR USEINTRODUCTIONWe would like to thank you for making a smart decision! The Blood Glucose Monitoring System is des

Pagina 2 - Reference:

810) Press the“>” button or “<” button until the correct hour is displayed.11) Press the “S” button. The minutes flash.12) Press the“>”

Pagina 3

92.3 Alarm setting1) Press the “<” button(Left arrow button)≧3 seconds on the front of the meter. MLS2)2) You will hear a beep, and the meter

Pagina 4 - 1.1 Contents

To quickly adjust a certain number, keep pressing the “>” or “<”button until the one you want appears.At any steps if you want to

Pagina 5 - Test Strip Specifications :

11MLSC4)Medi+SureTM5) When the control bottle symbol flashes on the meter, it means that you can start testing. You have 3 minutes to apply t

Pagina 6 - Battery Cover

12(1)(2)(3)(4)(5)(6)(8)(9)(10)1) Wash your hands with soap and warm water and dry them thoroughly. Remove the lancing devices cover.2) Place a

Pagina 7

132.6 Testing Your Blood Glucose1) Take one test strip out of the test strip vial. Replace the vial cap immediately and close it tightly.

Pagina 8

146) Pick up the meter and use the most comfortable way to touch the blood drop to the edge of the application point of the test strip. The

Pagina 9 - Temperature Units

15If you get a high or low reading and you do not feel ill ;• Repeat your measurement.• Make sure your readings are in mg/dL.• Test your meter with

Pagina 10

STEP1: CLEAN BEFORE DISINFECTING1.Dispense CaviWipes towelette.2.Clean surface of your device including meter and lacing device (not shown) with tow

Pagina 11 - * Steps to set the alarms :

*Why is the disinfection of this device required?The FDA in the USA has issued a new regulation regardingpublic health notifications highlighting the

Pagina 12 - 2.4 Testing Control Samples

IMPORTANT SAFETY INSTRUCITONS: Reference:1. “FDA Public Health Notification: Use of Fingerstick Devices on More than One Person Poses Risk for Tr

Pagina 13 - * Fingertip Blood Sampling :

* Information of CaviWipe disinfectantCaviWipes Disinfecting Towelettes were purchased from METREX RESEARCH CORP, and the EPA Reg. is 46781-8. CaviWip

Pagina 14

192.8 Reviewing Results in Memory1) Press the “M” button(main button)to turn on the meter.2) When the test strip symbol flashes, press the “M”

Pagina 15

206) At 7 days average result, press the “M” button again, you can read test results in memory, the latest test result will be shown for one m

Pagina 16 - Sampling Window

2121days28daysMemMemMemMemMemDelALLMemDelMem If you want to turn off the meter while you are in the memory and average, you can press the “S” butt

Pagina 17

222.9 Viewing Date, Time or Temperature1) Press the “<” button(Left arrow button)date, time and clock symbol( ) will be shown on the screen f

Pagina 18

23Section 3. Important Notes3.1 Caring for Your MeterTaking care of your meter is very simple. Just follow the guidelines shown below:1) Do not disa

Pagina 19 - Display Cover

24• All-symbol Message :3.3 Explanation of DisplaysWhen you press the “M” button or insert a test strip into the meter, all symbols willbe displayed

Pagina 20

25• Sample Application Message :This requires you to apply the blood sample or control solution to the test strip after inserting a test strip. A

Pagina 21

26You can select mmol/L in setting mode. The units will be displayed along with the test result.MemMem• Units of Test Result :3.4 Error Messages &am

Pagina 22

27Cause:Damaged meter.Action:Contact your local authorized distributor of Blood Glucose Monitoring System.E-O, E-OO, E-tF, E-SCause:

Pagina 23

Blood Glucose Monitoring System2467910111922232324262828Expected Values 1Blood SamplingAlarm settingViewing Date, Time, or TemperatureTesting Control

Pagina 24

283.5 Expected ValuesExpected blood glucose levels for people without diabetes:TimeRange (mmol/L)fasting 3.9-6.1less than 7.8 Two hours after meal

Pagina 26 - 3.3 Explanation of Displays

If you pick up this book, please contact above.

Pagina 28

2Section 1. Contents & Specifications1.2 Product Specifications & Operating ConditionsStorage ConditionsMemory CapacityMeasurement UnitDispl

Pagina 29 - E-O, E-OO, E-tF, E-S

3System Operation Conditions :Test Strips Operation ConditionsTemperature:50~104°F(10~40°C)Humidity 20%~80%RH.Using the Blood Glucose Test Strips only

Pagina 30 - 3.6 Meter Warranty

4 Blood Glucose Meter (back) :1.3 About the systemLCD DisplayShow blood glucose test results and messagesLeft Arrow Button /Time d

Pagina 31

5How to assess that enough blood has been sampled ? Look at the sampling window on the test strip.If you have enough blood on the strip, you willno

Pagina 32

6Section 2. How Your System Works2.1 Installing / Relacing the BatteryYour Blood Glucose Monitoring System is packed with one 3-volt li

Pagina 33

72.2 Setting the Year, Date, Time, and Temperature Units* Steps to set the Year, Date, Time, and Temperature Units :1) Press the “S” butt